Barco CRT Television MCFD 1219 MCFD 1219 TS User Manual

B4100528 / 03  
November2005  
MFCD 1219 - MFCD 1219 TS  
Installation & User Manual  
 
SAFETY INSTRUCTIONS  
• Adapter manufacturer:  
Linearity Electronics Co.  
Ltd., Model: LAD6019AB5,  
complies with UL Certified  
Class 2 Power adapter or  
UL Certified ITE Power  
adapter with LPS, and  
Suitable ratings.  
• Read the safety and  
the user will be required to  
correct the interference at  
his own expense.  
PowerSupplyCord-Listed,  
Detachable,maximum4.5m  
(14.76 ft.) long; rated  
minimum 125 V, 2.5 A, Type  
SPT-1 flexible cord; one end  
terminates in parallel blade  
(NEMA 5-20P) grounding-  
type attachment plug, other  
end in appliance coupler.  
operatinginstructionsbefore  
operating the apparatus.  
Retainsafetyandoperating  
instructions for future  
reference.  
This Class  
B
digital  
apparatus complies with  
Canadian ICES-003.  
Cet appareil numérique de  
la classe B est conforme à la  
normeNMB-003duCanada.  
• Adhere to all warnings on  
the apparatus and in the  
operating  
manual.  
instructions  
• Follow all instructions for  
operation and use.  
Water and moisture  
Never expose the  
Power connection  
•Thisapparatusconformsto:  
apparatustorainormoisture.  
• Never use the apparatus  
near water - e.g. near a  
UL60950,  
cUL60950,  
Warning: This apparatus  
must be earthed!  
Power requirements:  
IEC60950, CE  
bathtub,  
washbasin,  
swimmingpool,kitchensink,  
laundry tub or in a wet  
basement.  
connect the apparatus to an  
AC voltage as indicated at  
its back. Using a lower  
voltage, the apparatus will  
notbeabletooperate.Using  
• FCC notice  
This equipment has been  
tested and found to comply  
with the limits of a class B  
digital device, pursuant to  
Part 15 of the FCC rules.  
These limits are designed to  
Ventilation  
• Do not cover or block the  
ventilation openings in the  
cover of the set. When  
installing the apparatus in a  
cupboard or another closed  
location,heedthenecessary  
space between the set and  
the sides of the cupboard.  
a
higher voltage may  
damage the apparatus.  
Ifyouarenotsureofthetype  
of power supplied, consult  
the power company.  
Donotoverloadwalloutlets  
and extension cords as this  
may result in fire or electric  
shock.  
Mainsleadprotection(U.S.:  
Power cord): Supply cords  
shouldberoutedsothatthey  
are not likely to be walked  
upon or pinched by items  
placeduponoragainstthem,  
payingparticularattentionto  
cords at plugs and  
receptacles.  
provide  
reasonable  
protection against harmful  
interference when the  
equipment is operated in a  
commercial environment.  
This equipment generates,  
uses and can radiate radio  
frequency energy and, if not  
installed and used in  
accordance with the  
instruction manual, may  
cause harmful interference  
to radio communications.  
Operation of this equipment  
in a residential area is likely  
Installation  
• Place the apparatus on a  
flat, solid and stable surface  
thatcanbeartheweightofat  
least 3 monitors. If you use  
an unstable cart or stand,  
the set may fall, causing  
serious injury to a child or  
adult, and serious damage  
to the equipment.  
to  
cause  
harmful  
interference in which case  
© 2005 BARCO nv. Allrights reserved.  
 
CONTENTS  
1. Overview ....................................................................................................... 5  
1.1 Introduction ............................................................................................. 5  
Multi-scan capabilities ............................................................................... 5  
Touch panel ............................................................................................... 6  
1.2 Package contents ................................................................................... 6  
Power Saving ............................................................................................. 6  
1.3 Controls and connectors............................................................................ 7  
2. Installation .................................................................................................... 8  
2.1 Precautions ............................................................................................. 8  
2.2 Wall mounting ......................................................................................... 8  
Step 1: Remove the panel from the foot .................................................... 8  
Step 2: Fix the mounting plate to the wall .................................................. 8  
Step 3: Place the panel on the mounting plate ......................................... 9  
2.3 Connecting the signals......................................................................... 10  
To connect the video & sync signals: ...................................................... 10  
To connect the power:.............................................................................. 10  
2.5 Install the software .................................................................................11  
2.4 Starting up ..............................................................................................11  
3.On-screen display (OSD) menus ............................................................... 12  
3.1 How to use the OSD ............................................................................. 12  
3.2 Description of the menu items ............................................................. 13  
Main menu ............................................................................................... 13  
Color Menu .............................................................................................. 14  
Clock Menu .............................................................................................. 15  
4. Maintenance ............................................................................................... 16  
Panel........................................................................................................ 16  
Cabinet .................................................................................................... 16  
Touch panel ............................................................................................. 16  
Appendix A: Possible resolutions .................................................................. 17  
Appendix B: Technical specifications ............................................................. 18  
MFCD 1219 (TS) User's Guide  
4
 
1. OVERVIEW  
1.1 Introduction  
The MFCD 1219 (TS), BARCO’s full color 19”  
LCD display, guarantees perfect image quality in  
medical imaging applications.  
The display combines a TFT (thin film transistor)  
liquid crystal display panel structure and a built-in  
backlight with inverter for a better picture quality.  
It is designed to meet users' needs for  
performance, consistency, and outstanding image  
quality through a streamlined development  
process in which wall-mount functionality  
provides a variety of capability.  
The image on the display can be adjusted by  
means of the extended on-screen menu system  
(OSD).  
The internal memory can contain settings for 24  
different types of video signals (with different  
timings). 22 are factory-preset, 2 are user-  
definable.  
The display accepts the most common display  
standards. However, it is limited to the following  
specifications:  
Multi-scan capabilities  
Analog video:  
The horizontal frequency must be between 31  
and 91 kHz, the vertical frequency between 56  
and 85 Hz.  
Digital video:  
The horizontal frequency must be between 31.47  
and 64 kHz, the vertical frequency between 60  
and 70 Hz.  
The optimum and recommended resolution is  
1280 x 1024 / 60 Hz.  
MFCD 1219 (TS) User's Guide  
5
 
The monitor comes with a power saving feature;  
therefore, you may put the monitor into a power  
saving state when it is not in use. This feature  
complies with both EPA‘s Energy Star  
Power Saving  
requirements and European NUTEK/TCO’s  
power management guidelines. It conforms to  
Video Electronics Standard Association (VESA)  
approved DPMS power-down signaling method.  
This monitor automatically cuts down power  
consumption of monitor set when not detecting  
Hsync or Vsync signals. This feature is compliant  
with VESA DPMS.  
The MFCD 1219 TS is equipped with a touch  
panel. Instructions on how to install and use the  
touch panel driver and controls can be found in  
the "TouchKit, Barco TouchScreen controller  
installation and user manual" on the supplied  
CD-ROM.  
Touch panel  
1.2 Package contents  
The package should include the following items,  
please check. If some of the items are missing,  
please contact the reseller you have purchased  
the unit from.  
-
-
-
-
-
-
-
-
-
-
The display with foot  
12V DC adapter  
European power cord  
American power cord  
UK power cord  
Video cables: VGA cable and DVI-D cable  
Mounting plate with 4 screws  
This user manual  
Calibration software CD-ROM  
USB cable for touch panel  
MFCD 1219 (TS) User's Guide  
6
 
1.3 Controls and connectors  
(10)  
(1)  
(2)  
(3)  
(4)  
(5)  
(6)  
(7) (8)  
(9)  
(1) 12V DC power input  
(2) Analog video input  
(3) DVI input (DVI-D supported only)  
(4) USB port for touch panel connection to PC  
(MFCD 1219 TS only)  
(5) Menu key  
(6) <-> Key  
(7) <+> Key  
(8) Power LED  
The LED is off when the display is off.  
The LED is green when the display is on.  
The LED is orange when the display is in  
power-saving mode (stand-by)  
(9) Power key  
(10) Push-button to release the panel from the  
foot  
MFCD 1219 (TS) User's Guide  
7
 
2. INSTALLATION  
2.1 Precautions  
Keep your original packaging. It is designed for this  
display and is the ideal protection during transport.  
Avoid reflections in the flat panel to reduce eye  
strain.  
Place the display on a strong and stable table or  
desk.  
Keep the display away from heat sources and  
provide enough ventilation in case it is built in a rack  
or console. Do not put in direct sunlight.  
Make sure computer and display are switched off  
before connecting the signals.  
Touch panel precautions: Operate with a stylus (tip  
R0.8 or over, maximum hardness 3H), or with a  
finger without applying excessive load. Sharp  
edged or hard articles are prohibited. The gathering  
of dew in the panel may occur with abrupt  
temperature or humidity changes. A stable  
environment condition is recommended. Keep the  
surface clean. No adhesives should be applied.  
Avoid high voltage and static charge.  
2.2 Wall mounting  
You can mount the panel to the wall instead of to  
the foot, by means of the supplied mounting  
plate. If you do not need to mount the panel to  
the wall, please skip this item.  
Step 1: Remove the panel from the foot  
1
Position one hand under the panel at the  
front side. Position the other hand at the  
rear, under the push-button with BARCO  
logo (9).  
2
3
Firmly press down the push-button (9) with  
one hand while carefully lifting the panel up  
with the other hand.  
Remove the panel from the foot.  
Step 2: Fix the mounting plate to the wall  
1
Screw the mounting plate to the wall with  
the 4 supplied screws (A).  
MFCD 1219 (TS) User's Guide  
8
 
A
2
Slide back the locks at both sides of the  
mounting plate (B). In that way, you can  
secure the panel to the mounting plate after  
placing the panel.  
B
Step 3: Place the panel on the mounting  
plate  
1
Place the panel on the mounting plate (C). If  
you want to secure the panel to the  
mounting plate, place the  
panel in the frontmost  
notches.  
Please make sure that the  
four shafts are securely  
placed in the notches of the  
mounting plate.  
C
MFCD 1219 (TS) User's Guide  
9
 
2
To secure the panel, slide forward the  
locks on both sides of the mounting plate.  
Lock the panel with one screw at both  
sides (D).  
D
2.3 Connecting the signals  
To connect the video & sync signals:  
1
Connect one end of the appropriate video  
cable to the corresponding video input of  
the monitor.  
Analog video: Connect to input (2)  
DVI: Connect to input (3)  
2
Connect the other end of the video cable to  
the video output of your video source.  
Analog video: Computer graphics board  
with analog video output  
DVI: Computer graphics board with digital  
video output  
(1)  
(2)  
(3)  
To connect the power:  
1
2
3
Connect one end of the proper power cable  
to the AC input of the 12V DC adapter.  
Connect the 12V supply of the 12V DC  
adapter to the DC input (1) of the monitor.  
Connect the other end of the power cord to  
a grounded power outlet.  
MFCD 1219 (TS) User's Guide  
10  
 
2.4 Starting up  
Proceed as follows:  
1
2
Switch on the computer.  
Switch on the display by pushing the Power  
key (8).  
3
If necessary, select a suitable resolution in  
the computer operating system. Please  
refer to Appendix A, "Possible resolutions"  
in the back of this manual.  
Note: The recommended resolution for best  
image quality is 1280x1024 at 60 Hz.  
The microcontroller in the display checks if the  
connected video signal has been adjusted before,  
and if these adjustments have been stored in the  
memory. There are 2 possibilities:  
(8)  
a) The video signal has been adjusted and  
stored in the memory.  
In this case, the display switches to this memory  
location (the so-called mode) and the image will  
need no further adjustments.  
b) The video signal has not been adjusted and  
stored yet.  
In this case, the display will auto-size the picture  
and store the settings in one of the user modes.  
2.5 Install the software  
NioWatch software:  
Insert the CD-ROM in the CD-ROM drive. The  
CD-ROM starts automatically. Please follow the  
instructions on the screen.  
The CD-ROM contains user instructions about the  
usage of the NioWatch.  
Touch panel software:  
Please refer to the TouchKit installation & user  
manual on CD-ROM.  
MFCD 1219 (TS) User's Guide  
11  
 
3. ON-SCREEN DISPLAY (OSD)  
MENUS  
3.1 How to use the OSD  
Proceed as follows:  
1
Press the Menu key (4) on the front to display  
the OSD main menu.  
Note:  
It may be possible that the OSD menu does  
not appear. If this is the case, the front  
Controls are locked. To unlock them, please  
follow the procedure described in § 3.2 below.  
2
3
Press the <+> key (6) or <-> key (5) to scroll to  
the desired menu item.  
Press the Menu key (4) to activate the  
selected function or to enter the selected  
secondary menu.  
(5)  
(4)  
(6)  
4
5
If you have activated a function:  
a)Press the <+> key (6) or <-> key (5) to  
change the value.  
b)Press the Menu key (4) to enter the new  
value and return to the menu.  
To exit the OSD while saving the changes,  
select Save & Exit.  
To exit the OSD without saving the changes,  
select Cancel.  
Note: The OSD disappears  
Main Menu  
automatically after an  
inactivity period of 30  
seconds.  
- (Down)  
Brightness  
Contrast  
+ (Up)  
Highlighted bar  
35  
50  
Auto Adjust  
H Position  
V Position  
Color  
75  
29  
>
The color of the highlight bar  
indicates the status of the mode.  
Clock  
>
RED indicates the function is  
selected and ready to be  
adjusted.  
Languages  
Input Type  
>
>
Lock Controls  
Cancel  
Blinking RED indicates OSD is in  
parameter adjusting mode.  
Save & Exit  
MFCD 1219 (TS) User's Guide  
12  
 
3.2 Description of the menu items  
Main menu  
Function  
Description  
Brightness  
To adjust the overall image and  
background brightness level.  
Contrast  
To adjust the image brightness in  
relation to the background  
(the background is unchanged).  
Auto Adjust *  
To automatically set the H Position,  
V Position and Clock.  
Horizontal Position To move the screen horizontally  
left or right.  
Vertical Position  
Color  
To move the screen vertically  
upward or downward.  
To adjust parameters for the screen  
colors of Red, Green and Blue.  
Clock  
To adjust the function only when  
characteristics are blurred.  
Languages  
To select English, French, Italian,  
German or Spanish for OSD  
language.  
Input Type  
To select Analog (A1) or  
DVI-Digital (D) input source.  
Lock Controls **  
When locked, the OSD menu will not  
appear when pressing the Menu key.  
Cancel  
To restore the previous setting.  
Save & Exit  
To save the adjustments and quit the  
OSD menu.  
*Auto Adjust function will be automatically  
executed whenever the system is switched to a  
new mode. When the system is changed to this  
mode again later on, the system will not repeat the  
Auto Adjust function. This function is only valid  
when the mode concerned is selected for the first  
time.  
MFCD 1219 (TS) User's Guide  
13  
 
**To unlock the Controls, proceed as follows:  
1
2
Press the Power key to switch off the display  
With one hand, press and hold the <+> and  
the <-> key at the same time.  
With the other hand, press the Power key  
shortly to switch the display on again.  
3
4
Keep holding the <+> and the <-> key for  
about 3 seconds.  
At last, release the <+> and the <-> key.  
Now, by pressing the Menu key, the OSD  
menu will appear.  
Note:  
The bottom line of the OSD shows the input type,  
current resolution of the monitor and status of  
vertical sync. If it shows user mode, one of the  
user modes is selected.  
Color Menu  
Color Menu  
Function  
Description  
- (Down)  
Auto Balance  
+ (Up)  
Auto Balance  
To automatically adjust the contrast  
level of RGB. This does not support  
resolution of Mac 832 x 624 at 75Hz.  
68  
65  
70  
>
Red  
Green  
Blue  
Main Menu  
A1 1024 x 768 - 60.1 48.4k  
R
To adjust the level of color Red.  
To adjust the level of color Green.  
To adjust the level of color Blue.  
To return to Main Menu.  
G
B
Main Menu  
MFCD 1219 (TS) User's Guide  
14  
 
To perform the Autobalance function, you need  
to select a proper test pattern before performing  
the function.  
Proceed as follows:  
1
You must have installed the Barco  
NioWatch software.  
2
3
Right-click on the NioWatch systray icon.  
Select Test Patterns from the pop-up  
menu.  
4
5
Select the SMPTE test pattern.  
Now perform the function Autobalance  
from the MFCD 1219 (TS) control panel.  
6
When finished, click on the test pattern to  
close it.  
Clock Menu  
Function  
Description  
Clock Menu  
- (Down)  
OSD Position  
Clock  
+ (Up)  
OSD Position To display the OSD to your preferred  
position.  
1344  
4
>
Clock Phase  
Main Menu  
A1 1024 x 768 - 60.1 48.4k  
Clock  
To adjust the function only when  
characteristics are blurred.  
Clock Phase  
Main Menu  
To adjust ADC sampling clock phase.  
To return to Main Menu.  
MFCD 1219 (TS) User's Guide  
15  
 
4. MAINTENANCE  
Panel  
Take care not to damage or scratch the panel.  
Clean with a soft woolen or cotton towel. Use a  
watery solution or a mild commercial glass  
cleaning solution.  
Cabinet  
Do not use chemical cleaning products,  
benzene, toluene, xylene or other solvents.  
Clean with a soft cloth dampened with mild  
detergent and water. Repeat this with water only  
and wipe dry with a dry cloth.  
Touch panel  
(Only for MFCD 1219 TS)  
Use a clean and soft clothe with neutral  
detergent or with ethanol for cleaning.  
Do not use any chemical solvent, acidic or alkali  
solution.  
Avoid spilling liquid inside the display. Apply the  
liquid to the cloth, not to the panel.  
MFCD 1219 (TS) User's Guide  
16  
 
APPENDIX A: POSSIBLE  
RESOLUTIONS  
There are 22 preset modes and 2 user modes.  
The following modes are preset as factory  
defaults.  
Resolution  
Pixel  
Horizontal Vertical  
Standard  
Analog Digital  
Freq. (MHz) Freq. (kHz) Freq. (Hz)  
640 x 350  
640 x 480  
25.175  
25.175  
30.24  
31.50  
31.50  
36.00  
28.321  
36.00  
40.00  
50.00  
49.50  
56.25  
57.29  
65.00  
75.00  
78.80  
80  
31.47  
31.47  
35.00  
37.90  
37.50  
43.30  
31.47  
35.10  
37.88  
48.10  
46.88  
53.70  
49.80  
48.36  
56.50  
60.02  
60.24  
68.70  
67.50  
63.98  
80  
70  
60  
67  
72  
75  
83  
70  
56  
60  
72  
75  
85  
74.6  
60  
70  
75  
75  
85  
75  
60  
75  
85  
VGA  
VGA/VESA  
Mac  
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
VESA  
VESA  
VESA  
VGA  
720 x 400  
800 x 600  
V
V
VESA  
VESA  
VESA  
VESA  
VESA  
Mac  
832 x 624  
1024 x 768  
VESA  
VESA  
VESA/CRUS  
Mac  
V
94.50  
108  
VESA  
VESA  
VESA  
VESA  
VESA  
1152 x 864  
1280 x 1024  
108  
V
135  
157.5  
91.146  
MFCD 1219 (TS) User's Guide  
17  
 
APPENDIX B: TECHNICAL  
SPECIFICATIONS  
Picture panel  
Input signals  
19-inch diagonal viewable screen  
TFT (thin film transistor) active matrix,  
color liquid crystal display, RGB  
interface  
Analog: Hor. 31.47 to 91.2 kHz  
Vert. 56 to 85 Hz  
Sync types: Separate sync,  
composite sync, sync on  
Green  
Touch panel (MFCD 1219 TS only)  
Resistive technology  
Digital: Hor. 31.47 to 64 kHz  
Vert. 60 to 70 Hz  
Interface: USB 1.1  
Input mode: stylus or finger  
Touch active force (stylus 0.8 mm):  
<=50g  
Max. video input bandwidth  
157.5 MHz  
Resolution  
Signal system  
1280 x 1024 (native)  
Analog RGB signals, DVI digital  
Display area (H x V)  
Front panel controls  
376 x 301 (mm)  
Menu, - (down / decrease), + (up /  
increase), Power  
Pixel Pitch  
0.294 mm (H) x 0.294 mm (V)  
Input connectors  
15-pin D-sub  
Display color  
16M  
(for PC graphic signal input)  
3P - Mini – DIN – Power –Connector  
(for DC 12V, 6.5A input)  
Luminance  
DVI connector (supporting DVI-D only)  
280 cd/m2 (typ.)  
MFCD 1219 TS: 230 cd/m² (typ.)  
Power source  
Contrast ratio  
100 ~ 240 VAC  
700:1 (typ.)  
Power consumption  
50 W (max.)  
Response time  
9 ms (typ. avg.)  
Less than 5 W in power-off mode  
Viewing angle  
Power saving  
Vertical: 176º (typ.)  
Horizontal: 176º (typ.)  
VESA DPMS standard  
EPA/Energy Star compliant  
MFCD 1219 (TS) User's Guide  
18  
 
PnP compatibility  
NOTICE:  
VESA DDC 2B standards compliant  
DUE TO OUR POLICY OF  
CONTINUOUS PRODUCT  
IMPROVEMENT, THEABOVE  
SPECIFICATIONS ARE SUBJECTED  
TO CHANGE WITHOUT NOTICE.  
BARCO SHALL NOT BE LIABLE  
FOR TECHNICAL OR EDITORIAL  
ERRORS OR OMISSIONS  
CONTAINED HEREIN; NOR FOR  
INCIDENTAL OR CONSEQUENTIAL  
DAMAGES WHATSOEVER  
RESULTING FROM FURNISHING,  
PERFORMANCE OR USE OF THIS  
MATERIAL.  
Safety standards  
UL60950, cUL60950, IEC60950, CE,  
CCC  
Dimensions (W x H x D)  
450 mm x 461.8 mm x 213.9 mm  
Net weight  
7.7 kg  
MFCD 1219 TS: 8.3 kg  
Operating Temperature  
0°C to 40°C  
Storage Temperature  
-20°C to 60°C  
MFCD 1219 (TS) User's Guide  
19  
 
 

AEG Washer L 71470 FL User Manual
Aiphone Telephone MK 2SD User Manual
Alienware Laptop 17 R1 User Manual
Allied Telesis Network Router AR400 User Manual
Aluratek Digital Photo Frame ADMPF007F User Manual
Amana Freezer 1 82034 002 User Manual
American Standard Outdoor Shower 1660200 User Manual
Avocent Switch SC420 User Manual
Axis Communications Security Camera axis p54 ptz dome network camera series User Manual
Behringer Microphone A50 26313 00002 User Manual